CCB HOME>PRODUCTS>MD SERIES>CCB12MD-0.8


 

FEATURES

* Maintenance Free

* Leak Proof / Spill Proof

* Gas Recombination

* Absorbed Electrolyte

* Float / Cycle Use

* Low Self Discharge Rate

* Safety Valve

* Lead Calcium Alloy

* Useable In Any Position

* Rugged Design

* Available Flame Retardent Material (Optional)


VRLA 12V 0.8Ah - Specifications

Nominal Voltage

Rated Capacity @20hr rate

Maximum Charge Rate

Maximum Discharge Amps 5 sec.

Internal Resistance

12V

0.8Ah

0.40Amps

22.50Amps

140Mili Ohms

Capacity
@ 77
ºF (25ºC)

0.80Ah @ 20 hour rate (40mA) to 1.75 volts per cell

0.70Ah @ 10 hour rate (70mA) to 1.75 volts per cell

0.60Ah @ 5 hour rate (120mA) to 1.75 volts per cell

0.54Ah @ 3 hour rate (180mA) to 1.75 volts per cell

0.45Ah @ 1 hour rate (450mA) to 1.75 volts per cell

Dimensions

Length

96mm (3.78inches)

Width

25mm (0.98inches)

Height

62mm (2.44inches)

Total Height

62mm (2.44inches)

Weight

0.34kg (0.75lbs)

Operating Temperature Range

Discharge

-4ºF (-20ºC) to +140ºF (60ºC)

Charge

14ºF (-10ºC) to +122ºF (50ºC). (with temperature compensation)

Recommended Operating Temperature Range

+68ºF (20ºC) to +77ºF (25ºC).

Charging (Constant Voltage)

Cycle use

Initial Current 0.16Amps (recommended).

Voltage 14.5-14.9Volts @77ºF (25ºC)

Float use

Voltage 13.6-13.8Volts @77ºF (25ºC)

Self Discharge
@ 77
ºF (25ºC)

Capacity after 3 month storage

90%

Capacity after 6 month storage

80%

Capacity after 12 month storage

60%

CCB Battery may be stored for up to 12 months at 77ºF (25ºC) and then a freshing charge is required. For higher temperatures the time interval will be shorter.

Capacity affected by Temperature (20 hour rate)

104ºF (40ºC)

102%

77ºF (25ºC)

100%

32ºF (0ºC)

85%

58ºF (-15ºC)

65%

Notice: The above data are average values, and could be obtained within 3 charge / discharge cycles.These are not minimum values.

CCB BATTERY * * * THE ENGINE OF PROGRESS... ...