CCB HOME>PRODUCTS>MD SERIES>CCB12CD-18


 

FEATURES

* Maintenance Free

* Leak Proof / Spill Proof

* Gas Recombination

* Absorbed Electrolyte

* Float / Cycle Use

* Low Self Discharge Rate

* Safety Valve

* Lead Calcium Alloy

* Useable In Any Position

* Rugged Design

* Available Flame Retardent Material (Optional)


VRLA 12V18Ah - Specifications

Nominal Voltage

Rated Capacity @20hr rate

Maximum Charge Rate

Maximum Discharge Amps 5 sec.

Internal Resistance

12V

18Ah

9Amps

250Amps

14Mili Ohms

Capacity
@ 77
F (25C)

18.00Ah @ 20 hour rate (900mA) to 1.75 volts per cell

16.70Ah @ 10 hour rate (1.67A) to 1.75 volts per cell

15.30Ah @ 5 hour rate (3.06A) to 1.75 volts per cell

13.80Ah @ 3 hour rate (4.60A) to 1.75 volts per cell

11.00Ah @ 1 hour rate (11.00A) to 1.75 volts per cell

Dimensions

Length

180mm (7.09inches)

Width

76mm (3.00inches)

Height

167mm (6.58inches)

Total Height

167mm (6.58inches)

Weight

5.96kg (13.12lbs)

Operating Temperature Range

Discharge

-4F (-20C) to +140F (60C)

Charge

14F (-10C) to +122F (50C). (with temperature compensation)

Recommonded Operating Temperature Range

+68F (20C) to +77F (25C).

Charging (Constant Voltage)

Cycle use

Initial Current 3.6Amps (recommended).

Voltage 14.5-14.9Volts @77F (25C)

Float use

Voltage 13.6-13.8Volts @77F (25C)

Self Discharge
@ 77
F (25C)

Capacity after 3 month storage

90%

Capacity after 6 month storage

80%

Capacity after 12 month storage

60%

CCB Battery may be stored for up to 12 months at 77F (25C) and then a freshing charge is required. For higher temperatures the time interval will be shorter.

Capacity affected by Temperature (20 hour rate)

104F (40C)

102%

77F (25C)

100%

32F (0C)

85%

58F (-15C)

65%

Notice: The above data are average values, and could be obtained within 3 charge / discharge cylcles.These are not minimum values.

CCB12CD-18Plan

Discharge Curves

Discharging Current&Duration Time

Click here for larger size image!