CCB HOME>PRODUCTS>MD SERIES>CCB12MD-26


 

FEATURES

* Maintenance Free

* Leak Proof / Spill Proof

* Gas Recombination

* Absorbed Electrolyte

* Float / Cycle Use

* Low Self Discharge Rate

* Safety Valve

* Lead Calcium Alloy

* Useable In Any Position

* Rugged Design

* Available Flame Retardent Material (Optional)


VRLA 12V26Ah - Specifications

Nominal Voltage

Rated Capacity @20hr rate

Maximum Charge Rate

Maximum Discharge Amps 5 sec.

Internal Resistance

12V

26Ah

13Amps

288Amps

12Mili Ohms

Capacity
@ 77
F (25C)

26.00Ah @ 20 hour rate (1.30A) to 1.75 volts per cell

24.00Ah @ 10 hour rate (2.40A) to 1.75 volts per cell

22.80Ah @ 5 hour rate (4.56A) to 1.75 volts per cell

20.70Ah @ 3 hour rate (6.90A) to 1.75 volts per cell

17.50Ah @ 1 hour rate (17.50A) to 1.75 volts per cell

Dimensions

Length

165mm (6.50inches)

Width

175mm (6.89inches)

Height

125mm (4.93inches)

Total Height

125mm (4.93inches)

Weight

8.52kg (18.75lbs)

Operating Temperature Range

Discharge

-4F (-20C) to +140F (60C)

Charge

14F (-10C) to +122F (50C). (with temperature compensation)

Recommonded Operating Temperature Range

+68F (20C) to +77F (25C).

Charging (Constant Voltage)

Cycle use

Initial Current 5.2Amps (recommended).

Voltage 14.5-14.9Volts @77F (25C)

Float use

Voltage 13.6-13.8Volts @77F (25C)

Self Discharge
@ 77
F (25C)

Capacity after 3 month storage

90%

Capacity after 6 month storage

80%

Capacity after 12 month storage

60%

CCB Battery may be stored for up to 12 months at 77F (25C) and then a freshing charge is required. For higher temperatures the time interval will be shorter.

Capacity affected by Temperature (20 hour rate)

104F (40C)

102%

77F (25C)

100%

32F (0C)

85%

58F (-15C)

65%

Notice: The above data are average values, and could be obtained within 3 charge / discharge cylcles.These are not minimum values.

CCB12MD-26 Plan

Discharge Curves

Discharging Current&Duration Time

 

CCB BATTERY * * * THE ENGINE OF PROGRESS... ...