CCB HOME>PRODUCTS>MD SERIES>CCB12MD-5


 

FEATURES

* Maintenance Free

* Leak Proof / Spill Proof

* Gas Recombination

* Absorbed Electrolyte

* Float / Cycle Use

* Low Self Discharge Rate

* Safety Valve

* Lead Calcium Alloy

* Useable In Any Position

* Rugged Design

* Available Flame Retardent Material (Optional)


VRLA 12V5Ah - Specifications

Nominal Voltage

Rated Capacity @20hr rate

Maximum Charge Rate

Maximum Discharge Amps 5 sec.

Internal Resistance

12V

5Ah

2.5Amps

75Amps

40Mili Ohms

Capacity
@ 77
F (25C)

5.00Ah @ 20 hour rate (250mA) to 1.75 volts per cell

4.40Ah @ 10 hour rate (440mA) to 1.75 volts per cell

3.90Ah @ 5 hour rate (780mA) to 1.75 volts per cell

3.60Ah @ 3 hour rate (1.20A) to 1.75 volts per cell

3.00Ah @ 1 hour rate (3.00A) to 1.75 volts per cell

Dimensions

Length

90mm (3.55inches)

Width

70mm (2.76inches)

Height

101mm (3.98inches)

Total Height

107mm (4.22inches)

Weight

1.6kg (3.52lbs)

Operating Temperature Range

Discharge

-4F (-20C) to +140F (60C)

Charge

14F (-10C) to +122F (50C). (with temperature compensation)

Recommonded Operating Temperature Range

+68F (20C) to +77F (25C).

Charging (Constant Voltage)

Cycle use

Initial Current 1.0Amps (recommended).

Voltage 14.5-14.9Volts @77F (25C)

Float use

Voltage 13.6-13.8Volts @77F (25C)

Self Discharge
@ 77
F (25C)

Capacity after 3 month storage

90%

Capacity after 6 month storage

80%

Capacity after 12 month storage

60%

CCB Battery may be stored for up to 12 months at 77F (25C) and then a freshing charge is required. For higher temperatures the time interval will be shorter.

Capacity affected by Temperature (20 hour rate)

104F (40C)

102%

77F (25C)

100%

32F (0C)

85%

58F (-15C)

65%

Notice: The above data are average values, and could be obtained within 3 charge / discharge cylcles.These are not minimum values.

CCB BATTERY * * * THE ENGINE OF PROGRESS... ..