VRLA 12V90Ah - Specifications

Nominal Voltage

Rated Capacity @20hr rate

Maximum Charge Rate

Maximum Discharge Amps 5 sec.

Internal Resistance

12V

90Ah

45Amps

900Amps

4.3Mili Ohms

Capacity
@ 77
F (25C)

90.00Ah @ 20 hour rate (4.50A) to 1.75 volts per cell

81.00Ah @ 10 hour rate (8.10A) to 1.75 volts per cell

70.00Ah @ 5 hour rate (14.00A) to 1.75 volts per cell

63.00Ah @ 3 hour rate (21.00A) to 1.75 volts per cell

50.00Ah @ 1 hour rate (50.00A) to 1.75 volts per cell

Dimensions

Length

305mm (12.01inches)

Width

168mm (6.62inches)

Height

208mm (8.19inches)

Total Height

213mm (8.39inches)

Weight

28kg (61.60lbs)

Operating Temperature Range

Discharge

-4F (-20C) to +140F (60C)

Charge

14F (-10C) to +122F (50C). (with temperature compensation)

Recommonded Operating Temperature Range

+68F (20C) to +77F (25C).

Charging (Constant Voltage)

Cycle use

Initial Current 18Amps (recommended).

Voltage 14.5-14.9Volts @77F (25C)

Float use

Voltage 13.6-13.8Volts @77F (25C)

Self Discharge
@ 77
F (25C)

Capacity after 3 month storage

90%

Capacity after 6 month storage

80%

Capacity after 12 month storage

60%

CCB Battery may be stored for up to 12 months at 77F (25C) and then a freshing charge is required. For higher temperatures the time interval will be shorter.

Capacity affected by Temperature (20 hour rate)

104F (40C)

102%

77F (25C)

100%

32F (0C)

85%

58F (-15C)

65%

Notice: The above data are average values, and could be obtained within 3 charge / discharge cylcles.These are not minimum values.