VRLA 6V12Ah - Specifications

Nominal Voltage

Rated Capacity @20hr rate

Maximum Charge Rate

Maximum Discharge Amps 5 sec.

Internal Resistance

6V

12Ah

6Amps

180Amps

10Mili Ohms

Capacity
@ 77
F (25C)

12.00Ah @ 20 hour rate (600mA) to 1.75 volts per cell

10.80Ah @ 10 hour rate (1.08A) to 1.75 volts per cell

9.75Ah @ 5 hour rate (1.95A) to 1.75 volts per cell

9.30Ah @ 3 hour rate (3.10A) to 1.75 volts per cell

8.00Ah @ 1 hour rate (8.00A) to 1.75 volts per cell

Dimensions

Length

151mm (5.95inches)

Width

50mm (1.97inches)

Height

94mm (3.70inches)

Total Height

101mm (3.98inches)

Weight

2.00kg (4.40lbs)

Operating Temperature Range

Discharge

-4F (-20C) to +140F (60C)

Charge

14F (-10C) to +122F (50C). (with temperature compensation)

Recommonded Operating Temperature Range

+68F (20C) to +77F (25C).

Charging (Constant Voltage)

Cycle use

Initial Current 2.4Amps (recommended).

Voltage 7.25-7.45Volts @77F (25C)

Float use

Voltage 6.8-6.9Volts @77F (25C)

Self Discharge
@ 77
F (25C)

Capacity after 3 month storage

90%

Capacity after 6 month storage

80%

Capacity after 12 month storage

60%

CCB Battery may be stored for up to 12 months at 77F (25C) and then a freshing charge is required. For higher temperatures the time interval will be shorter.

Capacity affected by Temperature (20 hour rate)

104F (40C)

102%

77F (25C)

100%

32F (0C)

85%

58F (-15C)

65%

Notice: The above data are average values, and could be obtained within 3 charge / discharge cylcles.These are not minimum values.